Oxygen Plant With O2 Cylinder Filling Station

Oxygen Plant With O2 Cylinder Filling Station

Nuzhuo NZO Series
Send Inquiry
Chat Now
Description

NZO NUZHUO Series Oxigen Generation Equipment :

Nuzhuo 93-95 Purity Oxygen Plant Manufacturer Molecular sieve oxygen production system

In addition to the existing oxygen generator, we can also customize the oxygen generator system according to the installation situation of the customer's site, which can be installed on the customer's site.

Oxygen Generator

Oxygen

93 ±3%

Carbon Monoxide

<5ppm

Carbon Dioxide

<300ppm

Nitrogen Monoxide and Dioxide

<2ppm

Sulphur Dioxide

<1ppm

Oil

< 0.1 mg/m³

Water

<67ppm

Working dewpoint

- 46℃

PSA

Feature:

Medical molecular sieve oxygen generation system, professional in medical gas engineering, and reliable medical system fully meet the medical gas needs of various medical institutions.

1650605186(1)(1)

We will design specific configurations according to your requirements, according to your local altitude, humidity.

1653715057(1)

Project Internatinal Market :

1653725804(1)

Hope we can be your reliable partner in China~

FAQ:

The main problems of ordinary PSA oxygen generators:

1. The compressed air entering the adsorption tower contains a lot of harmful substances such as emulsion, and the damage to the zeolite molecular sieve is relatively serious.

2. The air flow generated by the compressed air entering the adsorption tower is large, which is easy to cause impact damage to the zeolite molecular sieve, which in turn leads to heavy pulverization of the zeolite molecular sieve.

3. The compression device installed in the adsorption tower has a large elastic pressure, which can cause extrusion damage to the zeolite molecular sieve, and the damage is more serious when the zeolite molecular sieve is damp.

4. Each adsorption cycle can separate up to 28% of the oxygen in the compressed air, which is almost double the difference compared with the NZO-PSA oxygen generator.

5. Most PSA oxygen generators do not have the conditions to provide oxygen for hyperbaric oxygen chambers. Most of the oxygen supply systems supply oxygen at a pressure of 0.5MPa. The terminal device for oxygen supply by nasal cannula in the ward will be damaged due to excessive pressure, which will eventually lead to a large increase in the oxygen leakage rate.

6. Without the technical conditions for monitoring the state of oxygen consumption, it is difficult to control the oxygen leakage in the central oxygen supply system in time. When there is a large oxygen leakage in the central oxygen supply system and there is no effective monitoring measures, it will inevitably lead to an increase in the operating load of the equipment and increase the use cost of oxygen.

7. When the service cycle of the ordinary PSA oxygen generator reaches 1-2 years, the oxygen production purity or oxygen production volume gradually begins to decline. At that time, if the normal oxygen supply is maintained, most of the oxygen concentration will be lower than 90% or 80%; if the oxygen concentration is maintained above 90%, the oxygen production can be reduced to about 80% of the initial use; Operational failures frequently occur in the process.

Hot Tags: Oxygen Plant With O2 Cylinder Filling Station, China Oxygen Plant With O2 Cylinder Filling Station manufacturers, factory